Which CLIA Certificate Do You Need for Blood Gases (pH, pO2, pCO2) Testing?
The CLIA certificate for Blood Gas depends on the complexity FDA assigned to your specific test system. Waived systems need at least a Certificate of Waiver; moderate or high complexity Blood Gas testing needs a Certificate of Compliance or a Certificate of Accreditation.
Step 1: find the complexity of your Blood Gas test system
Complexity is assigned to each test system, not to Blood Gas as an analyte. Search the FDA CLIA categorization database by test system name. Systems not on the lists are high complexity until categorized (42 CFR 493.17(c)(4)).
Check the exact Blood Gas analyzer and reagent in the FDA database before choosing a certificate.
Step 2: match the certificate
| Complexity of your Blood Gas system | CLIA certificate |
|---|---|
| Waived | Certificate of Waiver (or a higher certificate the lab already holds) |
| Moderate or high complexity | Certificate of Compliance (state survey) or Certificate of Accreditation (accrediting organization) |
A Provider-Performed Microscopy (PPM) certificate covers only specific microscopy procedures, not analyzer-based Blood Gas testing.
Step 3: CMS-116 and state rules
On Form CMS-116, nonwaived Blood Gas testing is listed under routine chemistry with your estimated annual volume. Some states add their own license; check with your state agency. Already certified? Ask your state agency or accrediting organization how to report a new test or specialty before you start.
What comes with nonwaived Blood Gas
- Blood Gases (pH, pO2, pCO2) is a regulated analyte (routine chemistry, 42 CFR 493.931). CLIA PT acceptance limit: pH: target value ±0.04; pCO2: target value ±8% or ±5 mm Hg (greater); pO2: target value ±15% or ±15 mmHg (greater).
- Qualified director and technical personnel (Subpart M).
- Method verification before patient testing (42 CFR 493.1253) and daily QC (42 CFR 493.1256).
Related tests
Full guide: Blood Gases (pH, pO2, pCO2) testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.
Starting a lab or changing your CLIA certificate?
Sound Lab Consultants helps new and growing laboratories choose the right certificate, complete the CMS-116 and state forms, and prepare for the first survey.
Related guides on soundlabconsult.com:
Frequently asked questions
What CLIA certificate do I need for Blood Gas testing?
It depends on the categorization of your Blood Gas test system: waived systems need at least a Certificate of Waiver; moderate or high complexity systems need a Certificate of Compliance or Accreditation.
Is Blood Gas testing waived?
Check the FDA database for your exact system. Complexity belongs to the test system, not the analyte.
Where do I list Blood Gas on the CMS-116?
Nonwaived Blood Gas testing goes under routine chemistry in the nonwaived testing section, with estimated annual test volume.